TEL 10-1211

TEL 10-1211

  • 厂商:

    TRACOPOWER

  • 封装:

    DIP6 模块

  • 描述:

    隔离模块 直流转换器 1 输出 5.1V 2A 9V - 18V 输入

  • 数据手册
  • 价格&库存
TEL 10-1211 数据手册
DC/DC Converter TEL 10 Series, 10 Watt • Most compact 10 Watt converter in DIP-16 metal casing • • Highest power density of 3.83 W/cm³ • • • Wide 2:1 input voltage range • • Built-in EN 55032 class A filter • 3-year product warranty 6-side shielded metal case with insulated base plate UL 62368-1 IEC 62368-1 High efficiency for low thermal loss Operating temperature range of -40°C to +88°C Current limitation and protection against short circuit The TEL 10 series is a range of isolated 10 Watt DC/DC converters which come in a ultra compact DIP-16 metal package. The design purpose of these series was to miniaturized low power DC/DC converters to the maximum without sacrificing high efficiency. The TEL 10 series sets the new standart for power density with 3.83 W/cm³. The TEL 10 series offers a wide 2:1 input voltage range and features a high efficiency of up to 88% which enables an operation temperature of up to +70°C at full load and up to 85°C with 50% load. The converters have an internal input filter to comply with conducted emission EN 55032 class A. The TEL 10 Series models feature an overall economical solution for space critical and cost sensitive applications in instrumentation, IT and industrial electronics. Models Order Code Input Voltage Range TEL 10-1210 TEL 10-1211 TEL 10-1212 TEL 10-1213 TEL 10-1215 TEL 10-1222 TEL 10-1223 TEL 10-2410 TEL 10-2411 TEL 10-2412 TEL 10-2413 TEL 10-2415 TEL 10-2422 TEL 10-2423 TEL 10-4810 TEL 10-4811 TEL 10-4812 TEL 10-4813 TEL 10-4815 TEL 10-4822 TEL 10-4823 www.tracopower.com 9 - 18 VDC (12 VDC nom.) 18 - 36 VDC (24 VDC nom.) 36 - 75 VDC (48 VDC nom.) Output 1 Output 2 Vnom Imax 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA September 20, 2023 Vnom Efficiency Imax –12 VDC –15 VDC 416 mA 333 mA –12 VDC –15 VDC 416 mA 333 mA –12 VDC –15 VDC 416 mA 333 mA typ. 79 % 82 % 86 % 87 % 87 % 86 % 86 % 80 % 83 % 87 % 88 % 88 % 87 % 87 % 80 % 83 % 87 % 88 % 88 % 87 % 87 % Page 1 / 4 TEL 10 Series, 10 Watt Input Specifications Input Current - At no load 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: 12 Vin models: 24 Vin models: 48 Vin models: - At full load Surge Voltage Under Voltage Lockout Recommended Input Fuse Input Filter 20 mA typ. 10 mA typ. 8 mA typ. 970 mA typ. 480 mA typ. 240 mA typ. 25 VDC max. (1 s max.) 50 VDC max. (1 s max.) 100 VDC max. (1 s max.) 7 VDC min. / 8 VDC typ. 15 VDC min. / 16 VDC typ. 31 VDC min. / 34 VDC typ. 2'000 mA (slow blow) 1'000 mA (slow blow) 500 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Internal Pi-Type Output Specifications Voltage Set Accuracy Regulation - Input Variation (Vmin - Vmax) - Load Variation (0 - 100%) Ripple and Noise (20 MHz Bandwidth) - Cross Regulation (25% / 100% asym. load) - single output - dual output - single output - dual output Capacitive Load - single output - dual output ±1% max. 0.8% max. 0.8% max. 1% max. 2% max. (Output 1) 2% max. (Output 2) dual output models: 5% max. single output models: dual output models: single output models: dual output models: 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: 3.3 Vout models: 5.1 Vout models: 12 Vout models: 15 Vout models: 24 Vout models: 12 / -12 Vout models: 15 / -15 Vout models: Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation 60 mVp-p typ. 60 mVp-p typ. 80 mVp-p typ. 80 mVp-p typ. 80 mVp-p typ. 80 / 80 mVp-p typ. 80 / 80 mVp-p typ. 72 mVp-p max. 72 mVp-p max. 96 mVp-p max. 96 mVp-p max. 96 mVp-p max. 96 / 96 mVp-p max. 96 / 96 mVp-p max. 2'600 µF max. 1'300 µF max. 560 µF max. 560 µF max. 200 µF max. 390 / 390 µF max. 200 / 200 µF max. Not required ±0.02 %/K max. 30 ms typ. / 60 ms max. Continuous, Automatic recovery 192% max. of Iout max. 160% typ. of Iout max. All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 2 / 4 TEL 10 Series, 10 Watt Transient Response 5% max. (25% Load Step) 500 µs max. (25% Load Step) - Response Deviation - Response Time Safety Specifications Safety Standards EN 62368-1 IEC 62368-1 UL 62368-1 www.tracopower.com/overview/tel10 PD 3 - IT / Multimedia Equipment - Certification Documents Pollution Degree EMC Specifications EMI Emissions - Conducted Emissions - Radiated Emissions External filter proposal: EMS Immunity - Electrostatic Discharge Air: Contact: - RF Electromagnetic Field - EFT (Burst) / Surge External filter proposal: - Conducted RF Disturbances - PF Magnetic Field Continuous: 1 s: EN 55032 class A (internal filter) EN 55032 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) www.tracopower.com/overview/tel10 EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 20 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A www.tracopower.com/overview/tel10 EN 61000-4-6, 10 Vrms, perf. criteria A EN 61000-4-8, 100 A/m, perf. criteria A EN 61000-4-8, 1000 A/m, perf. criteria A General Specifications Relative Humidity Temperature Ranges Power Derating - Operating Temperature - Case Temperature - Storage Temperature - High Temperature Cooling System Altitude During Operation Switching Frequency Insulation System Isolation Test Voltage Isolation Resistance Isolation Capacitance Reliability Washing Process Housing Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type - Input to Output, 60 s - Input to Output, 1 s - Input to Case, 60 s - Output to Case, 60 s - Input to Output, 500 VDC - Input to Output, 100 kHz, 1 V - Calculated MTBF 95% max. (non condensing) –40°C to +85°C +105°C max. –50°C to +125°C Depending on model See application note: www.tracopower.com/overview/tel10 Natural convection (20 LFM) 6'000 m max. 357 - 483 kHz (PWM) 420 kHz typ. (PWM) Functional Insulation 1'500 VDC 1'800 VDC 1'000 VDC 1'000 VDC 1'000 MΩ min. 1'500 pF max. 1'800'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf Alu alloy, black anodized coating Epoxy (UL 94 V-0 rated) Copper Alloy (C6801) Nickel (2 - 4 µm) Tin (3 - 5 µm), matte Metal Case All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com September 20, 2023 Page 3 / 4 TEL 10 Series, 10 Watt Mounting Type Connection Type Footprint Type Soldering Profile PCB Mount THD (Through-Hole Device) DIP16 Lead-Free Wave Soldering 260°C / 10 s max. 6.5 g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule).) c1447b21-5486-495a-bbc2-a25a5dae8cae Weight Environmental Compliance - REACH Declaration - RoHS Declaration - SCIP Reference Number Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tel10 Outline Dimensions 23.8 (0.94) 7 8 BOTTOM VIEW 16 10 13.7 (0.54) 10.16 (0.400) 1 Pinout 9 Pin Single Dual 1 –Vin (GND) –Vin (GND) 7 NC NC 8 NC Common 9 +Vout +Vout 10 –Vout –Vout 16 +Vin (Vcc) +Vin (Vcc) 15.24 (0.600) 2.54 1.77 3.0 (0.070) NC: Not connected (0.100) 3.8 Ø0.5 (Ø0.02) (0.15) 8.0 (0.31) (0.12) Dimensions in mm (inch) Tolerances: x.x ±0.5 (x.xx ±0.02) x.xx ±0.25 (x.xxx ±0.01) Pin diameter tolerances: x.x ±0.05 (x.xx ±0.002) © Copyright 2023 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. September 20, 2023 Page 4 / 4
TEL 10-1211 价格&库存

很抱歉,暂时无法提供与“TEL 10-1211”相匹配的价格&库存,您可以联系我们找货

免费人工找货